Monday, April 14, 2014

TRANE ERROR CODES

27 komentar
Malfunction Display Section
When malfunction or protection occurs in the air coditioner, corresponding code will be displayed on the screen of the indoor unit and the indicator of outdoor unit will blink accordingly as well.
When protection or mal function is eliminated, display will be back to normal.
9, 12 MBH - 60 and 50 Hz (No LED lights on outdoor PCB)
Code = 1
Malfunction = Storage slug
Error Display
Dual 8 display = EE
Led = Heating LED-pause 3s and blink 15 times
Repair Method = Replace indoor main board

Code = 2
Malfunction = Indoor PCB malfunction
Error Display
Dual 8 display = EE
Led = Heating LED-pause 3s and blink 15 times
Repair Method = Replace indoor main board

Code = 3
Malfunction = Anti-freezing protection
Error Display
Dual 8 display = E2
Led = Running LED pause 3s and blink 2 times
Repair Method = Outdoor ambient temperature too low

Code = 4
Malfunction = Overload of system
Error Display
Dual 8 display = H4
Led = Heating LED-pause 3s and blink 4 times
Repair Method = System abnormal, check if the evaporator and codenser is dirty and blocked

Code = 5
Malfunction = No motor of indoor unit feedback
Error Display
Dual 8 display = H6
Led = Running LED-pause 3s and blink 11 times
Repair Method = Is electro motor mounted normally?

Code = 6
Malfunction = Indoor pipe temperature sensor malfunction
Error Display
Dual 8 display = F2
Led = Cooling LED-pause 3s and blink 2 times
Repair Method = Is it loose? Measure the resistant value with universal meter

Code = 7
Malfunction = Internal ambient temperature sensor malfunction
Error Display
Dual 8 display = F1
Led = Cooling LED-pause 3s and blink 1 times
Repair Method = Is it loose? Measure the resistant value with universal meter

Code = 8
Malfunction = Zero passage abnormal
Error Display
Dual 8 display = UF
Led = Heating and cooling LED blink 7 times at the same time
Repair Method = Replace indoor main board

Code = 9
Malfunction = Overload of compressor
Error Display
Dual 8 display = H3
Led = Heating LED-pause 3s and blink 3 times
Repair Method = Inspect connection state of the overload wire

Code = 10
Malfunction = Startup failure
Error Display
Dual 8 display = Lc
Led = Heating LED-pause 3s and blink 11 times
Repair Method = Check if the resistance of compressor to ground is normal, the outdoor main board may be wrong.

Code = 11
Malfunction = No motor of outdoor unit feedback
Error Display
Dual 8 display = UH
Led = Heating and cooling LED blink 8 times at the same time
Repair Method = This malfunction may happen when outdoor DC electromotor is used

Code = 12
Malfunction = Overcurrent protection
Error Display
Dual 8 display = E5
Led = Running LED-pause 3s and blink 5 times
Repair Method = Is electric network variable?

Code = 13
Malfunction = 4-way valve conversion abnormal
Error Display
Dual 8 display = U7
Led = Cooling LED-pause 3s and blink 20 times
Repair Method = Replace 4-way valve

Code = 14
Malfunction = Phase current detection malfunction of compressor
Error Display
Dual 8 display = U1
Led = Heating LED-pause 3s and blink 13 times
Repair Method = Replace outdoor mainboard

Code = 15
Malfunction = Sync failure
Error Display
Dual 8 display = H7
Led = Heating LED-pause 3s and blink 7 times
Repair Method = Check if the resistance of compressor and resistance to ground is normal, if the compressor is normal, the outdoor main board may be wrong

Code = 16
Malfunction = Current diction malfunction of complete unit
Error Display
Dual 8 display = U5
Led = Cooling LED-pause 3s and blink 13 times
Repair Method = Replace outdoor main board

Code = 17
Malfunction = Outdoor ambient temperature sensor malfunction
Error Display
Dual 8 display = F3
Led = Cooling LED-pause 3s and blink 3 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter

Code = 18
Malfunction = Discharge protection of compressor
Error Display
Dual 8 display = E4
Led = Running LED-pause 3s and blink 4 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter

Code = 19
Malfunction = Break-circuit and short-circuit of outdoor discharge temperature sensor
Error Display
Dual 8 display = F5
Led = Cooling LED-pause 3s and blink 5 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter

Code = 20
Malfunction = Break-circuit and short-circuit of outdoor condenser temperature sensor
Error Display
Dual 8 display = F4
Led = Cooling LED-pause 3s and blink 18 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter

Code = 21
Malfunction = Overheat of carbon fin
Error Display
Dual 8 display = P8
Led = Heating LED-pause 3s and blink 19 times
Repair Method = Is outdoor ambient temperature is too high? I radiator mounted correctly?

Code = 22
Malfunction = DC overcurrent
Error Display
Dual 8 display = UU
Led = Heating and cooling LED blink 11 times at the same time
Repair Method =

Code = 23
Malfunction = Temperature sensor malfunction of carbon fin
Error Display
Dual 8 display = P7
Led = Heating LED-pause 3s and blink 18 times
Repair Method = Replace outdoor main board

Code = 24
Malfunction = Lack of Freon or block protection
Error Display
Dual 8 display = F0
Led = Cooling LED-pause 3s and blink 10 times
Repair Method =

Code = 25
Malfunction = DC input voltage is too high
Error Display
Dual 8 display = PH
Led = Cooling LED-pause 3s and blink 11 times
Repair Method = Is voltage of AC power supply normal?

Code = 26
Malfunction = DC input voltage is too low
Error Display
Dual 8 display = PL
Led = Heating LED-pause 3s and blink 21 times
Repair Method = Is voltage of AC power supply normal?

Code = 27
Malfunction = Commuication malfunction
Error Display
Dual 8 display = E6
Led = Runing LED-pause 3s and blink 6 times
Repair Method = Is outdoor connecting wire reliably connected?

Code = 28
Malfunction = Setting error, indoor and outdoor unit abnormal
Error Display
Dual 8 display = UA
Led = Heating and coolig LED blink 12 times at the same time
Repair Method = Outdoor unit is not mached with indoor unit
Remarks 4min after protection stop of compressor, the malfunction is shown in error code.
In other situation, the malfunction will be displayed by press the light button for 6 times within 4s
Read More ->>

Wednesday, April 9, 2014

DuraChill™ Air and Water Cooled 5, 7.5 and 10 HP Chillers

4 komentar
Display, Alarm and Error Messages
When an alarm or error condition is detected, “Ft” appears in the left display and a corresponding code flashes on the right display. Operational limit
parameter alarms will shut down compressor, fan, pump and heaters. Alphabetical codes will also appear on the right display. An audio alarm will also sound.
After taking corrective action, restart unit to clear fault or error.

Code = 02
Description = Low limit temperature alarm
Action required = Alarm – Process fluid temperature has dropped below low limit temperature setting. Increase heat load or decrease “LL” low temperature alarm setting.
Default = 39ºF (4ºC)

Code = 03
Description = High limit temperature alarm
Action required = Alarm – Process fluid temperature has reached high temperature limit setting.
Decrease heat load or increase “HL” high temperature alarm setting.
Default = 95ºF (35ºC)

Code = 04
Description = Over-Temperature Alarm (Select Models Only)
Action required = Alarm – Process fluid temperature is above factory set high temperature cutout.
On air-cooled condenser units the cutout will reset automatically after the temperature of the fluid is lowered. On water-cooled condenser
units the cutout must be manually reset after the temperature of the fluid is lowered. A red button is accessible through the rear panel.
Default = Units without heater option “OTP” jumpered on PCB

Code = 05
Description = Low liquid level alarm (Select Models Only)
Action required = Delayed Alarm – Activated when the liquid level in the reservoir falls below an acceptable level for 30 seconds. On units with the liquid level float switch option. Wired in series with mechanical flow switch – see “07 Low Flow Alarm”
Default = See Fuse Bit Setting 5.4

Code = 07
Description = Low Flow Alarm
Action required = Alarm – Flow rate has dropped below minimum flow rate setting.
Correct cause of low flow rate or decrease “FL” minimum flow rate setting (See “FL” Section 5.4)
Secondary – Mechanical Flow Switch closes with flow (~4 GPM Minimum). If installed in combination with optional water level float
switch they are wired in series and both must be closed, if either opens due to low water level or low flow this alarm or “EFL” Flow Error (See “EFL” below) may be activated.
Default = ~4 GPM Minimum Required for Flow Switch

Code = 08
Description = High Pressure Alarm
Action required = Delayed Alarm – Activated when fluid outlet pressure has exceeded high pressure limit setting for 30 seconds.
Decrease outlet pressure or raise “FP” fluid pressure limit setting.
Default = 100 PSI 689 kPa

Code = 09
Description = Internal software fault
Action required = Fault – Default unit to ºC or ºF, if fault persists replace Control PCB
NOTE: Some parameters will reset to default values – this could activate another fault code if is cleared. Review and return all parameters to usersettings.
Default = N/A

Code = 10
Description = Triac fault
Action required = Fault – Default unit to ºC or ºF, if fault persists replace Control PCB
NOTE: Some parameters will reset to default values – this could activate another fault code if is cleared. Review and return all parameters to user settings.
Default = N/A

Code = 11
Description = Internal RTD probe fault
Action required = Fault – RTD Sensor, check for open or shorted sensor (Reference resistance values 100[ (ohms) @ 0ºC / 138.51[ @ 100ºC If probe tests good, replace control PCB.
Default = N/A
Code = 12
Description = External RTD probe fault
Action required = Fault – RTD Sensor, check for open or shorted sensor (Reference resistance values 100[ (ohms) @ 0ºC / 138.51[ @ 100ºC If probe tests good, replace control PCB.
Default = N/A

Code = 13
Description = Communications fault
Action required = Fault – Default unit to ºC or ºF, if fault persists replace Control PCB
NOTE: Some parameters will reset to default values – this could activate another fault code if is cleared. Review and return all parameters to user settings.
Default = N/A

Code = 14
Description = ADC fault, internal probe
Action required = Fault – Default unit to ºC or ºF, if fault persists replace Control PCB
NOTE: Some parameters will reset to default values – this could activate another fault code if is cleared. Review and return all parameters to user settings.
Default = N/A

Code = 15
Description = ADC fault, external probe
Action required = Fault – Default unit to ºC or ºF, if fault persists replace Control PCB
NOTE: Some parameters will reset to default values – this could activate another fault code if is cleared. Review and return all parameters to user settings.
Default = N/A

Code = 16
Description = Front Panel – High Ambient Temperature Alarm
Action required = Alarm – Maximum ambient temperature limit. Displayed and settable only in ºC.
NOTE: Air-Cooled Chiller’s rated cooling capacity is dependent on an ambient temperature below 104ºF (40ºC) and performance will
decrease as the ambient temperature rises. Continuous operation at ambient temperatures above 104ºF (40ºC) is not recommend for any air or water cooled chiller.
Default = 45ºC

Code = 17
Description = Rear Panel – High Ambient Temperature Alarm (Select Models Only)
Action required = Alarm – Maximum ambient temperature limit. Displayed and settable only in ºC.
NOTE: Air-Cooled Chiller’s rated cooling capacity is dependent on an ambient temperature below 104ºF (40ºC) and performance will
decrease as the ambient temperature rises. Continuous operation at ambient temperatures above 104ºF (40ºC) is not recommend for any air or water cooled chiller.
Default = 45ºC

Code = 18
Description = Ambient Temperature Probe (P3) Fault (Select Models Only)
Action required = Fault – RTD Sensor, check for open or shorted sensor (Reference resistance values 100[ (ohms) @ 0ºC / 138.51[ @ 100ºC If probe tests good, replace control PCB.
Default = N/A

Code = 19
Description = Pump Overload (DAP1) Fault
Action required = Pump – Check continuity across “DAP1” on PCB through NO contacts on overload relay, reset overload relay, and check pump fuses.
Default = N/A

Code = 20
Description = Compressor Overload (DAF2)
Action required = Compressor Pressure Sensors – See Troubleshooting 7.5.
Default = N/A

Code = 21
Description = Fan Overload (DAF1) Fault
Action required = Fan(s) – Check continuity across “DAF1” on PCB through NO contacts on overload relay(s), reset overload relay, check fan(s) fuses. NOTE: On 10 HP Chillers both overload relays NO contacts wired in series with “DAF1”.
Default = N/A

Code = 22
Description = Pump 2 Overload (DAP2) Fault (Select Models Only)
Action required = Pump 2 Option only – Check continuity through NO contacts on overload relay, reset overload relay, check “Pump 2 Fuses”.
Default = “DAP2” jumpered on PCB

The alarms below will be displayed in the right hand display.
Code = EFL
Description = Low fluid level or Low fluid flow
Action required = Warning / Alarm – Audible alarm will sound 5 times, once every 8 seconds. If alarm condition continues the unit will shut down.
- Fluid level too low for units with fluid level float switch.
- Fluid flow too low for units with flow switch (“P0” no pump - no reservoir option).
Default =

Code = EHA
Description = High Ambient Temperature Alarm
Action required = Alarm – The ambient temperature (measured on Control PCB) is higher the high ambient temperature setting.
Lower the ambient temperature or increase the “HA” temperature limit setting.
Default = 45ºC

Code = EHL
Description = High limit temperature alarm
Action required = Alarm – Process fluid temperature has reached high temperature limit setting.
Decrease heat load or increase “HL” high temperature alarm setting.
Default = 95ºF 35ºC

Code = ELL
Description = Low limit temperature alarm
Action required = Alarm – Process fluid temperature has dropped below low limit temperature setting.
Increase heat load or decrease “LL” low temperature alarm setting.
Default = 39ºF 4ºC

Code = LO H2O
Description = No fluid flow and pressure
Action required = Warning – Indicates the chiller did not detect any fluid flow or pressure upon startup. Unit will normally run after 5 minutes – leave chiller with error code displayed for 5 minutes.
Default =

The codes below will be displayed in the right display and indicate display control status.
Code = LLO
Description = Local Lockout
Action required = Normal – Indicates the Local Lockout feature has been enabled.
Prevents settings from accidentally being changed. To enable the local lockout feature “LLO”, press and hold the “Select / Set” knob until “LLO” is displayed (approximately 5 seconds).
Default =

Code = CAN
Description = Cancel Local Lockout
Action required = Normal – Appears when Local Lockout feature has been canceled. To cancel the local lockout feature, press and hold the “Select / Set” knob until “CAn” is displayed (approximately 5 seconds).
Default =

Code = EC
Description = External remote control active
Action required = Normal – Chiller in standby until remotely activated. (Option)
Default =

Automatic Restart from Alarm Mode
This Chiller is equipped with an automatic restart feature to avoid false alarms. If any alarm condition is detected the chiller will turn off, wait 30 seconds and then turn on.
This is to avoid nuisance trips due to temporary flow obstructions, temperature swings or electrical line noise.
Three restart attempts will be made. If the alarm condition continues to exist then an alarm will sound and the chiller will remain off until the problem is corrected.
Read More ->>

CLIMATIC™ 50 - CHILLERS ERROR CODES ALARMS

0 komentar
001 Flow Rate Water Evaporator
011 Electrical Heater(s)
012 High Outlet Water Temperature
013 Low Inlet Water Temperature
022 Low Outlet Water Temperature
023 High Inlet Water Temperature
040 Pump Flow
041 Pump 1
042 Pump 2
070 Clock card
071 BE50
081 Temperature Probe Water Inlet
083 Temperature Probe Outside
085 Temperature Probe Water Outlet
086 Temperature Probe Water Heat Recovery Inlet
087 Temperature Probe Water Heat Recovery Outlet
092 Circuit 1 Condenser fan
093 Circuit 2 Condenser fan
094 Circuit 3 Condenser fan
108 Correction Power factor
111 Circuit 1 Probe High Pressure
112 Circuit 1 Probe Low Pressure
114 Circuit 1 Compressor(s)
115 Circuit 1 High pressure
117 Circuit 1 Low pressure
118 Circuit 1 Risk of Frosting
121 Circuit 2 Probe High Pressure
122 Circuit 2 Probe Low Pressure
124 Circuit 2 Compressor(s)
125 Circuit 2 High pressure
127 Circuit 2 Low pressure
128 Circuit 2 Risk of Frosting
210 Circuit 1 EEV Driver
211 Circuit 1 EEV Low Superheat Temperature
214 Circuit 1 EEV L.O.P
215 Circuit 1 EEV Valve NOT Closed
216 Circuit 1 EEV Probe Low Pressure or Suction Temperature
217 Circuit 1 EEV Motor
219 Circuit 1 EEV Battery
220 Circuit 2 EEV Driver
221 Circuit 2 EEV Low Superheat Temperature
224 Circuit 2 EEV L.O.P
225 Circuit 2 EEV Valve NOT Closed
226 Circuit 2 EEV Probe Low Pressure or Suction Temperature
227 Circuit 2 EEV Motor
228 Circuit 2 EEV E.E.P.R.O.M
Read More ->>
 